Number 1 corresponds to Service Required, though you may just do it yourself. 8) Reset Time & Date. This indicates that your alarm panel has lost its time & date and needs to be reprogrammed. This usually occurs if the system powered all the way down. To set the time and date: Press the ‘.’ key followed by the ‘6’ key. Enter your 4-digit master code. Pres the ‘1’ key. A friend had a problem with there alarm,there is no paper work for this panal and no codes at all,the panel is in a lockable box with no keys. I have forced the box and the panel inside is a pc1832/1864 I believe to reset the panel you have to short out pgrm1 and z1,I have done this but this has not worked,don't no what else to try and there are at least 4 alarms in the same street with the.
- Dsc Alarm Panel Reset Code
- Dsc Alarm Panel Reset Time
- Dsc Alarm System Reset Master Code
- Resetting Dsc Alarm Panel
- Dsc Alarm Panel Manual
You can reset a DSC Impassa to factory defaults by first unplugging the AC transformer and disconnecting the battery to cut power. Then connect a jumper between inputs IO1 and IO2. Power up the panel, wait 10 seconds and power down. Then disconnect the jumper, and power the system back on.
Performing a factory default will restore all system settings to their default. It will also restore the Master Code to 1234 and the Installer Code to 5555. All zones that have been set up with the system will need to be reprogrammed, and all sensors will need to be relearned.
Complete the following steps to perform a factory default on a DSC Impassa Alarm System:
1. Power down the system. Start by opening up the DSC Impassa System. To do this, use a small screwdriver to press in the two bottom tabs on the front of the panel. Then carefully separate the front of the panel from the back. Disconnect the backup battery by unplugging it. Then unplug the AC transformer from the wall outlet. This will power down the system.
Dsc Alarm Panel Reset Code
2. Apply the jumper. Connect a jumper between inputs IO1 and IO2. These inputs are shown in the picture below:
3. Perform the default. Plug in the AC transformer to power the system back on. Wait at least 10 full seconds. Then unplug the transformer to power the system back down. This should factory default the system.
4. Confirm the default. Disconnect the jumper. Then reapply AC power. Check and confirm that the system has been restored to its factory default settings. If it has, reconnect the backup battery, and close the panel. It the default failed, repeat the process and try again.
An easy way to check if the default went through is to try using the default Installer Code to access programming. Press [*8] on the main screen. The screen will display 'Enter Your Installers Code'. Enter in the default code of 5555. If the system displays 'Enter Section', then the factory default was successful. If it says the code was invalid, then the default failed to go through.